13 screens and grilles shall be of corrosion resistant material.
High efficiency furnace exhaust direct vent termination clearances.
High efficiency or condensing furnaces exhaust the combustion gases and bring in fresh.
Vent pipe blocking the exhaust flow.
Table illustrations of the required space between a direct or side wall vent for a gas fired heating appliance and building windows doors corners gas meter air intakes sidewalks balconies.
Gas appliance direct vent clearances distances from direct gas vent to building features sidewall vent direct vent direct exhaust systems for gas fired heaters water heaters other appliances.
American gas association has certified the design of condensing furnaces for a minimum of 0 clearance from combustible materials with a single wall plastic vent pipe.
Exhaust vents must not be allowed to be obscured or hidden by vegetation.
Vegetation must not be allowed to grow within 3 feet of an exhaust vent.
Specifications errors in direct vent side wall vent condensing boiler or furnace vent installations.
Gas fireplace direct vent termination cap clearance distances clearances between the gas fireplace exhaust vent and other building components or features.
Traditional gas fired forced air furnaces produce hot combustion exhaust gasses and therefore need metal vent pipes or chimneys.
This article gives typical clearance distance requirements between the termination cap of a gas fireplace or fireplace insert and other building or site features such as windows doors other mechanical system components air intakes.
Exhaust vents must be protected against rain and equipped with back flow prevention features e g flap dampers.
In contrast modern high efficiency condensing furnaces exhaust much cooler gasses and need only plastic pipe materials such as pvc cpvc or abs for their exhaust vents some high efficiency furnaces also include a plastic pipe for intake area and all types.
In high efficiency models the lower temperature of the exhaust can allow moisture a by product of combustion to condense in the flue especially when outdoor temperatures drop into the 20 s or below.
14 the net free area of an air intake or exhaust outlet shall be equal to or greater than the cross sectional area of the duct served.
This article describes side wall vent systems for conventional mid range efficiency heating boilers furnaces water heaters we include for comparison low temperature side wall vent systems used by high efficiency or condensing boilers furnaces water heaters.
In all areas exhaust vents should be at least 1 foot above roof surface.
See direct vents side wall vents for a complete table of recommended clearance distances from a direct vent gas appliance terminal to other building.
Clearance to combustibles an unconfined space in some cases provision for combustion air and flue gas vent systems and clearance to neighboring buildings if sidewall venting is used.
Direct vent chimneys or exhaust for heating appliances.